Design Considerations
 
 
High Pressure Low Volume Compressed Air Pulse Jet Cleaning System
vs.
Low Pressure High Volume Reverse Air Cleaning System
Reverse Air Cleaning System Advantages:

• Generally recognized as preferred dust collection design for PRB low sulphur    coal application

• Does not have potential for freezing problems due to moisture in compressed    air cleaning system
• Tangential cyclonic inlet separates large particles, thereby reducing load on filter    bags
• For cold weather climates, casing is extended to ground to provide weather    proof enclosure (as shown on right)
• Conical hopper has less potential for bridging